17At maximum phase shift, the gain of any first-order RC network is zero. Both phase shift and attenuation in an RC lag network are frequency-dependent: as frequency increases, phase shift grows larger (from 0o to a maximum of −90o) and the output signal grows weaker. At its theoretical maximum phase shift of exactly −90o, the output signal would be reduced to nothing!